Product description
Standstill monitors and time relays; Included in standard version; Detects standstill using 1 or 2 impulse sensors; Uses additional standstill signal, e.g. PLC as second input channel; 2 safety contacts; 2 Signalling outputs
Product Details
- EMC rating 10 V/m
- Input signal, LOW Signal 0 0 … 2 VDC
- Conduction resistance, maximum 40 Ω
- Input signal, HIGH Signal 1 10 … 30 VDC
- Current, Utilisation category DC13 2 A
- Switching capacity, minimum 10 mA
- Contact resistance, maximum 0.1 Ω
- Switching capacity, maximum 2 A
- Voltage, Utilisation category AC15 230 VAC
- Voltage, Utilisation category DC13 24 VDC
- Rated control voltage at AC 60 Hz, maximum 26.4 VAC
- Current, Utilisation category AC-15 3 A
- Note (Contact resistance) in new state
- Rated AC voltage for controls, 60 Hz, minimum 20.4 VAC
- Rated AC voltage for controls at DC minimum 20.4 VDC
- Rated control voltage at AC 50 Hz, maximum 26.4 VAC
- Degree of pollution to VDE 0110 3
- Rated AC voltage for controls, 50 Hz, minimum 20.4 VAC
- Overvoltage category II
- Thermal test current 6 A
- Storage and transport temperature, maximum +70 °C
- Rated operating voltage 24 VDC ± 15 %
- Resistance to vibrations to EN 60068-2-6 10 ... 55 Hz, Amplitude 0.35 mm
- Restistance to shock 30 g / 11 ms
- Degree of protection of clips or terminals IP20
- Storage and transport temperature, minimum -25 °C
- Degree of protection of the mounting space IP54
- Ambient temperature, maximum +55 °C
- Ambient temperature, minimum +0 °C
- Width 22.5 mm
- Depth 121 mm
- Degree of protection of the enclosure IP40
- Cable section, maximum 2.5 mm²
- Tightening torque of Clips 0.6 Nm
- Cable section, minimum 0.2 mm²
- Mechanical life, minimum 20,000,000 Operations
- Integral System Diagnostics, status Yes
- Number of signalling outputs 2
- Terminal designations IEC/EN 60947-1
- Number of LEDs 1
- Mounting Snaps onto standard DIN rail to EN 60715
- Number of safety contacts 2
- Number of undelayed semi-conductor outputs with signaling function 2
- Earth connection detection Yes
- Gross weight 200 g
- Wire breakage detection Yes
- Stop-Category 0
- Climatic stress EN 60068-2-3, BG-GS-ET-14
- Feedback circuit Yes
- Material of the contacts, electrical Ag-Ni 10 and 0.2 µm gold-plated
- Enclosure material Glass-fibre reinforced thermoplastic, ventilated
- Reset edge detection Yes
- Standards IEC/EN 60204-1, BG-GS-ET-20, EN ISO 13849-1
- Electrical power consumption, maximum 5 W
- Rated control voltage at DC, maximum 28.8 VDC
- Rated impulse withstand voltage Uimp 4.8 kV
- Height 100 mm
- Terminal Connector Screw connection, rigid or flexible
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
FWS 1206 C Related Documents
Manufacturer warranty
FWS 1206 C Schmersal
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
We deliver nationwide and international
Secure Payment Processing
Your Safety, Our Priority.
Warranty
Manufacturer warranty
Responsive Customer Support
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
About the manufacturer
Applied Automation is an authorized Schmersal distributor, proudly offering a diverse range of innovative safety and automation solutions tailored to meet the rigorous demands of modern industries. Schmersal is a globally renowned manufacturer specializing in the development and production of high-quality safety systems designed to protect both personnel and machinery across various industrial sec...
Recently viewed products
Relevant products
FAQ
Out if stock but available for backorder.
Standstill monitors and time relays; Included in standard version; Detects standstill using 1 or 2 impulse sensors; Uses additional standstill signal, e.g. PLC as second input channel; 2 safety contacts; 2 Signalling outputs
What can I help you find today?