SLG440AS-ER-0900-04 Schmersal Safety Light Curtains
Part#:SLG440AS-ER-0900-04
Manufacturer:Schmersal
Alt. Part#:103007557
Product Lifecycle:Active
Get a quick Quote!
SLG440AS-ER-0900-04 Schmersal - AS interface safety at work; Safety switchgear; Protection field height 900 mm; 4-beam; Safety type 4 in accordance with IEC 61496-1; Integrated AS-Interface; Range 0,3 … 12; Configurable blanking functions; Integrated status indicator
About the manufacturer: Schmersal is one of the manufacturers that offers Safety Light Curtains that you can order at Applied Automation site. Schmersal produces a wide range of high-quality switchgears specifically engineered to protect machinery and facilities in industrial automation and the elevator industry.
Check out the SLG440AS-ER-0900-04 Schmersal price in the box on the right side or send a quick quote.
Product Details
- Power consumption, Transmitter 75 mA
- Power consumption, Receiver 150 mA
- Rated operating voltage 24 VDC -15% / +10% (stabilised PELV)
- Note (AS-i Input module address) Preset to address 0, can be changed through AS-interface bus master or hand-held programming device
- AS-i Input module address 0
- AS-i Parameter bits, P2 No function
- Note (AS-i Parameter bits) Set the parameter outputs to "1111" (0xF), FID: periphery error
- AS-i Parameter bits, P3 Internal device error (FID)
- AS-i Parameter bits, P1 Low beam quality
- AS-i Parameter bits, P0 No function
- AS-i Outputs, DO 0 … DO 3 No Function
- AS-i Profile S-0.B.F.E
- AS-i Input, Channel 2 Data bits DI 2 / DI 3 = dynamic code transmission
- AS-i Input, Channel 1 Data bits DI 0 / DI 1 = dynamic code transmission
- AS-i Version V 3.0
- AS-i Specification Safety-Slave
- AS-i Current consumption, maximum 50 mA
- Note (AS-i Operating voltage) Protection against polarity reversal
- AS-i Operating voltage AS-i maximum 31.6 VDC
- AS-i Operating voltage, minimum 18 VDC
- Degree of pollution to VDE 0100 2
- Overvoltage category III
- Restistance to shock 10 g / 16 ms
- Protection rating III
- Rated impulse withstand voltage Uimp 0.8 kV
- Rated insulation voltage Ui 32 VDC
- Storage and transport temperature, maximum +70 °C
- Resistance to vibrations to EN 60068-2-6 10 … 55 Hz, amplitude 0.35 mm
- Length of sensor 33 mm
- Width of sensor 27.8 mm
- Storage and transport temperature, minimum -25 °C
- Height of Receiver 1,063 mm
- Ambient temperature, maximum +50 °C
- Degree of protection IP67 to EN 60529
- Ambient temperature, minimum -10 °C
- Height of transmitter 1,043 mm
- Terminal Connector Connector
- Terminal, Connector, Transmitter Connector plug M12, 4-pole
- Number of beams 4
- Terminal connector, Recipient Connector plug M12, 5-pole
- Range, protection field, minimum 300 mm
- Range, protection field, maximum 12,000 mm
- Detection ability for test bodies at v = 1.6 m/s 300 mm
- Wave length of the sensor 880 nm
- Integral System Diagnostics, status Yes
- Gross weight 1,630 g
- 7-segment display Yes
- Standards EN 50295, EN 62061, EN 61496-1
- Reaction time, maximum 18 ms
- Enclosure material Aluminium
- Hide function Yes
- Safety functions Yes
- Active principle optoelectronic
- Beam distance 300 mm
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
SLG440AS-ER-0900-04 Description
SLG440AS-ER-0900-04 Schmersal - AS interface safety at work; Safety switchgear; Protection field height 900 mm; 4-beam; Safety type 4 in accordance with IEC 61496-1; Integrated AS-Interface; Range 0,3 … 12; Configurable blanking functions; Integrated status indicator
Related documents SLG440AS-ER-0900-04 Specs
Manufacturer warranty
$1,828.00
Request a quote, and we will send availability within minutes.
Select Qty:
$1,828.00
$1,828.00 each
Average response time: 11 minutes
Fast Shipping & Delivery
We deliver nationwide and international
Secure Payment Processing
with money back guarantee
Warranty
Manufacturer warranty
Responsive Customer Support
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
What can I help you find today?