Solenoid interlocks; Hygienic design; Protection class IP 69; Suitable for mounting to profile systems; Thermoplastic enclosure; RFID-technology for needs-based protection against tampering; 3 different directions of actuation; Compact design; 3 LEDs to s

About the manufacturer: Schmersal is one of the manufacturers that offers Safety Switch Interlocks that you can order at Applied Automation site. Schmersal produces a wide range of high-quality switchgears specifically engineered to protect machinery and facilities in industrial automation and the elevator industry.

Check out the AZM300Z-I1-ST-SD2P-A Schmersal price in the box on the right side or send a quick quote.

Product Details

  • Test pulse interval, typical
    1000 ms
  • Classification ZVEI CB24I, Source
    C2
  • Current leakage Ir
    0.5 mA
  • Test pulse duration, maximum
    0.5 ms
  • Voltage, Utilisation category DC13
    24 VDC
  • Current, Utilisation category DC12
    0.05 A
  • Duration of risk, maximum
    200 ms
  • Enclosure material
    Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
  • Wiring capacity
    50 nF
  • Current, Utilisation category DC13
    0.05 A
  • Voltage, Utilisation category DC12
    24 VDC
  • Versions
    short-circuit proof, p-type
  • Voltage drop Ud, maximum
    4 V
  • Current consumption at 24V
    5 mA
  • Classification ZVEI CB24I, Sink
    C1, C2
  • Test pulse interval, minimum
    100 ms
  • Switching thresholds
    −3 V … 5 V (Low), 15 V … 30 V (High)
  • Duty cycle solenoid
    100 %
  • Current consumption with solenoid ON, average
    200 mA
  • Switching frequency, maximum
    0.5 Hz
  • External wiring and device fuse rating
    2 A gG
  • Required rated short-circuit current to EN 60947-5-1
    100 A
  • Notes (Power supply, general)
    stabilised PELV power supply
  • Current consumption with solenoid ON, peak
    350 mA / 200 ms
  • Degree of pollution to IEC/EN 60664-1
    3
  • No-load supply current I0
    100 mA
  • Operating voltage, maximum
    26.4 VDC
  • Overvoltage category
    III
  • Rated impulse withstand voltage Uimp
    0.8 kV
  • Rated insulation voltage Ui
    32 VDC
  • Protection rating
    III
  • Operating voltage, minimum
    20.4 VDC
  • Zulässige Aufstellhöhe über NN, maximum
    2,000 m
  • Restistance to shock
    30 g / 11 ms
  • Resistance to vibrations to EN 60068-2-6
    10 … 150 Hz, amplitude 0.35 mm
  • Storage and transport temperature, maximum
    +90 °C
  • Relative humidity, maximum
    93 %
  • Ambient temperature, maximum
    +60 °C
  • Note (Relative humidity)
    non-condensing, non-icing
  • Storage and transport temperature, minimum
    -10 °C
  • Ambient temperature, minimum
    +0 °C
  • Degree of protection
    IP66 to EN 60529, IP67 to EN 60529, IP69 to EN 60529
  • Height of sensor
    35 mm
  • Operation current
    150 mA
  • Note (series connection of the sensors)
    Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
  • Length of sensor
    120 mm
  • Width of sensor
    87.5 mm
  • Ensured switch distance OFF Sar
    20 mm
  • Terminal Connector
    Connector M12, 8-pole, A-coded
  • Length of sensor chain, maximum
    200 m
  • Note (length of the sensor chain)
    Cable length and cross-section change the voltage drop dependiing on the output current
  • Ensured switch distance ON Sao
    1 mm
  • Tightening torque for the fixing screws, maximum
    7 Nm
  • Switch distance
    2 mm
  • Type of the fixing screws
    2x M6
  • Clamping force in accordance with ISO14119 Fzh
    1,150 N
  • Latching force, adjustable, position 2
    50 N
  • Tightening torque of the fixing screws, minimum
    6 Nm
  • Latching force, adjustable, position 1
    25 N
  • Clamping force, maximum Fmax
    1,500 N
  • Angular offset between interlocking device and actuator, maximum
    2 °
  • Number of fail-safe digital outputs
    2
  • Series-wiring
    Yes
  • Integral System Diagnostics, status
    Yes
  • Mechanical life, minimum
    1,000,000 Operations
  • Safety functions
    Yes
  • Note (Mechanical lifetime)
    When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s)
  • Short-circuit recognition
    Yes
  • Latching
    Yes
  • Short circuit detection
    Yes
  • Manual release
    Yes
  • Serial diagnostics
    Yes
  • Guard locking monitored
    Yes
  • Response time safety outputs in case of switch-off by actuator, maximum
    100 ms
  • Response time safety outputs in case of switch-off by safety inputs, maximum
    1.5 ms
  • Power to lock
    Yes
  • Time to readiness, maximum
    5,000 ms
  • Frequency band RFID
    125 kHz
  • Standards
    EN ISO 13849-1, EN ISO 14119, IEC 60947-5-3
  • general information
    Individual coding
  • Active principle
    RFID
  • Transmit power, maximum
    -6 dB/m
  • Coding level according to ISO 14119
    High
  • Gross weight
    550 g

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Related documents AZM300Z-I1-ST-SD2P-A Specs

Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery

We deliver nationwide and international


Secure Payment Processing

with money back guarantee


Warranty

Manufacturer warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?