AZM300Z-I1-ST-1P2P-A Schmersal Safety Switches

AZM300Z-I1-ST-1P2P-A on Applied Automation
Schmersal

Part#:AZM300Z-I1-ST-1P2P-A

Alt. Part#:103001452

Manufacturer:Schmersal

Category:Safety Switches

Product Lifecycle:Active

Product description

Solenoid interlocks; Individual coding with RFID technology; Coding level "High" according to ISO 14119; Connector M12, 8-pole; Power to lock; Guard locking monitored; Diagnostic output; Hygienic design; Protection class IP 69; Suitable for mounting to pr

Product Details

  • Height of sensor
    35 mm
  • Width of sensor
    87.5 mm
  • Note (series connection of the sensors)
    Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
  • Length of sensor
    120 mm
  • Note (length of the sensor chain)
    Cable length and cross-section change the voltage drop dependiing on the output current
  • Terminal Connector
    Connector M12, 8-pole, A-coded
  • Length of sensor chain, maximum
    200 m
  • Ensured switch distance OFF Sar
    20 mm
  • Tightening torque for the fixing screws, maximum
    7 Nm
  • Ensured switch distance ON Sao
    1 mm
  • Tightening torque of the fixing screws, minimum
    6 Nm
  • Clamping force, maximum Fmax
    1,500 N
  • Clamping force in accordance with ISO14119 Fzh
    1,150 N
  • Type of the fixing screws
    2x M6
  • Latching force, adjustable, position 2
    50 N
  • Switch distance
    2 mm
  • Latching force, adjustable, position 1
    25 N
  • Mechanical life, minimum
    1,000,000 Operations
  • Note (Mechanical lifetime)
    When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s)
  • Angular offset between interlocking device and actuator, maximum
    2 °
  • Integral System Diagnostics, status
    Yes
  • Number of fail-safe digital outputs
    2
  • Safety functions
    Yes
  • Short-circuit recognition
    Yes
  • Series-wiring
    Yes
  • Latching
    Yes
  • Short circuit detection
    Yes
  • Manual release
    Yes
  • Guard locking monitored
    Yes
  • Duration of risk, maximum
    200 ms
  • Response time safety outputs in case of switch-off by actuator, maximum
    100 ms
  • Response time safety outputs in case of switch-off by safety inputs, maximum
    1.5 ms
  • Coding level according to ISO 14119
    High
  • Power to lock
    Yes
  • Test pulse interval, typical
    1000 ms
  • Current, Utilisation category DC13
    0.05 A
  • Voltage drop Ud, maximum
    4 V
  • Current leakage Ir
    0.5 mA
  • Current, Utilisation category DC12
    0.05 A
  • Voltage, Utilisation category DC13
    24 VDC
  • Versions
    short-circuit proof, p-type
  • Voltage, Utilisation category DC12
    24 VDC
  • Classification ZVEI CB24I, Sink
    C1, C2
  • Classification ZVEI CB24I, Source
    C2
  • Test pulse interval, minimum
    100 ms
  • Current consumption at 24V
    5 mA
  • Test pulse duration, maximum
    0.5 ms
  • Switching thresholds
    −3 V … 5 V (Low), 15 V … 30 V (High)
  • Duty cycle solenoid
    100 %
  • Switching frequency, maximum
    0.5 Hz
  • External wiring and device fuse rating
    2 A gG
  • Current consumption with solenoid ON, peak
    350 mA / 200 ms
  • Required rated short-circuit current to EN 60947-5-1
    100 A
  • Current consumption with solenoid ON, average
    200 mA
  • Operating voltage, maximum
    26.4 VDC
  • No-load supply current I0
    100 mA
  • Notes (Power supply, general)
    stabilised PELV power supply
  • Degree of pollution to IEC/EN 60664-1
    3
  • Operating voltage, minimum
    20.4 VDC
  • Overvoltage category
    III
  • Rated impulse withstand voltage Uimp
    0.8 kV
  • Rated insulation voltage Ui
    32 VDC
  • Zulässige Aufstellhöhe über NN, maximum
    2,000 m
  • Resistance to vibrations to EN 60068-2-6
    10 … 150 Hz, amplitude 0.35 mm
  • Protection rating
    III
  • Restistance to shock
    30 g / 11 ms
  • Note (Relative humidity)
    non-condensing, non-icing
  • Relative humidity, maximum
    93 %
  • Storage and transport temperature, maximum
    +90 °C
  • Storage and transport temperature, minimum
    -10 °C
  • Ambient temperature, maximum
    +60 °C
  • Ambient temperature, minimum
    +0 °C
  • Degree of protection
    IP66 to EN 60529, IP67 to EN 60529, IP69 to EN 60529
  • Standards
    IEC 61508, IEC 60947-5-3, EN ISO 13849-1
  • Time to readiness, maximum
    5,000 ms
  • Active principle
    RFID
  • Transmit power, maximum
    -6 dB/m
  • Frequency band RFID
    125 kHz
  • general information
    Individual coding
  • Enclosure material
    Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
  • Gross weight
    550 g

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



AZM300Z-I1-ST-1P2P-A Related Documents

Manufacturer warranty

AZM300Z-I1-ST-1P2P-A Schmersal

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery

We deliver nationwide and international


Secure Payment Processing

Your Safety, Our Priority.


Warranty

Manufacturer warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

About the manufacturer

Schmersal

Applied Automation is an authorized Schmersal distributor, proudly offering a diverse range of innovative safety and automation solutions tailored to meet the rigorous demands of modern industries. Schmersal is a globally renowned manufacturer specializing in the development and production of high-quality safety systems designed to protect both personnel and machinery across various industrial sec...

Recently viewed products

Relevant products

FAQ

Out if stock but available for backorder.

Solenoid interlocks; Individual coding with RFID technology; Coding level "High" according to ISO 14119; Connector M12, 8-pole; Power to lock; Guard locking monitored; Diagnostic output; Hygienic design; Protection class IP 69; Suitable for mounting to pr

What can I help you find today?